B Braun Medical, Inc. APEX Compounding System Control Panel Module, REF: 601224, Product Code AX1000 - Product Usage: intended for intravascular administration to a patient. Recall
Check Your Product
According to the U.S. Food and Drug Administration (FDA)
Product
APEX Compounding System Control Panel Module, REF: 601224, Product Code AX1000 - Product Usage: intended for intravascular administration to a patient.
Brand
B Braun Medical, Inc.
Lot Codes / Batch Numbers
All APEX Compounding System with Software Version 1.0.5.57 or earlier
Products Sold
All APEX Compounding System with Software Version 1.0.5.57 or earlier
B Braun Medical, Inc. is recalling APEX Compounding System Control Panel Module, REF: 601224, Product Code AX1000 - Product Usage: inte due to There is the potential for the compounding system to not immediately interrupt compounding and alert user to the presence of an air bubble exceeding 3. Based on FDA medical device recall database.
Summary derived from FDA notice
Reason for Recall
As stated by FDA
There is the potential for the compounding system to not immediately interrupt compounding and alert user to the presence of an air bubble exceeding 3% of the ordered volume for an ingredient. This could result in a a compounded drug that does not meet the specified accuracy range for an individual ingredient.
Recommended Action
Per FDA guidance
On Nov. 23, 2020, the firm issued a "Urgent Medical Device Correction" letter to affected consignees via USPS mail. In addition to informing consignees about the recall device, the firm requested consignees take the following actions: 1. Review the URGENT MEDICAL DEVICE CORRECTION Notification in its entirety and ensure that all users in your organization and other concerned persons are informed about this voluntary Medical Device Correction and the affected product(s). 2. Ensure workflow(s) are in place to review air bubbles and scrap any final containers which exceed your facilitys guidelines until your APEX Compounding System has been upgraded to Software Version 1.0.5.58 or higher. " When compounding is complete, if bubbles were detected, APEX activates the Bubble Events button on the Compounding Complete screen allowing you to review the bubbles detected during compounding. " Until such time as your APEX software has been updated, BBMI recommends having qualified pharmacy personnel review this screen prior to removing the final container to ensure that the size of any air bubbles are within an allowable range per your facilitys guidelines. " Alternatively, your facility can have qualified personnel review each Compounding Activity Report generated by the device which also contains air bubble information. " Instructions for viewing the Bubble Events screen are provided in Attachment 02 of this Notice. Instructions for printing and reviewing the Compounding Activity Report are provided in Attachment 03 of this Notice. " Any final containers which exceed your facilitys allowable range should be scrapped. 3. Return the completed Acknowledgement Medical Device Correction form to BBMI by utilizing the enclosed self-addressed envelope or via scanned e-mail to BBMUS_Carrollton_QualitySystemManagement@bbraunusa.com within two (2) weeks of receipt, even if the total inventory in your possession is zero (0). It is important this form is
Verify this information on the official source
For complete details and official instructions, check the U.S. Food and Drug Administration (FDA) directly.