Beckman Coulter Inc. Active Cortisol EIA, 96 Wells, DSL-10-2000 The DSL-10-2000 Active Cortisol Enzyme Immunoassay (EIA) kit provides materials for the quantitative measurement of cortisol in serum, plasma or urine. This assay is intended for in vitro diagnostic use. Recall
Check Your Product
According to the U.S. Food and Drug Administration (FDA)
Product
Active Cortisol EIA, 96 Wells, DSL-10-2000 The DSL-10-2000 Active Cortisol Enzyme Immunoassay (EIA) kit provides materials for the quantitative measurement of cortisol in serum, plasma or urine. This assay is intended for in vitro diagnostic use.
Brand
Beckman Coulter Inc.
Lot Codes / Batch Numbers
Not specified in FDA notice. Check official source for details.
Products Sold
Lot Numbers Epiration Dates 04195 8/15/2006 04195A 10/18/2006 04195B 1/26/2006 04195D 8/15/2006 04195E 10/18/2006 04195F 10/18/2006 09266A 01/31/2006 09266 10/17/2007 04126A 10/11/2007 04126 7/28/2007 03066A 09/05/2007 03066 09/05/2007 01036 07/02/2007 716217 06/06/2008 716218 07/29/2008 800408 05/07/2009 800409 05/07/2009 800410 05/07/2009 890829 09/03/2009 990168 09/03/2009
Beckman Coulter Inc. is recalling Active Cortisol EIA, 96 Wells, DSL-10-2000 The DSL-10-2000 Active Cortisol Enzyme Immunoassay (EIA) due to The recall was initiated because Beckman Coulter has confirmed that the listed lot numbers of Active Control ELISA reagent will result in falsely high. Based on FDA medical device recall database.
Summary derived from FDA notice
Reason for Recall
As stated by FDA
The recall was initiated because Beckman Coulter has confirmed that the listed lot numbers of Active Control ELISA reagent will result in falsely high values for patient samples due to a shift in the calibration of the assigned standard values. Beckman Coulter recommends that patient results, generated with the affected lots, be evaluated in the context of other diagnostic tests and the clinica
Recommended Action
Per FDA guidance
Beckman Coulter sent a Product Corrective Action (PCA) letter dated July 13, 2009. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to discontinue use until further notice and discard remaining affected product. Customers were instructed to contact Beckman Coulter at 1-800-231-7970. Newer lots (lot number 991069 or higher) of the product have been recalibrated to restore the performance as described in the Instructions for Use (IFU). For method correlation information, please contact Technical Support at the phone number listed below. Consignees were asked to share this information with laboratory staff and retain the PCA letter for their Quality System documentation, and complete and return the enclosed Response Form within 10 days so that the firm can be assured that they received the notification. Questions regarding this notification were directed to the DSL Technical Support Center at 1-800-231-7970 in the United State and Canada, or their local Beckman Coulter Representative.
Verify this information on the official source
For complete details and official instructions, check the U.S. Food and Drug Administration (FDA) directly.