Aruba IV Boilers (Crown Boiler) – carbon monoxide risk (2024)
Hazard assessment based on recall description.
This AI-generated summary is provided for general informational purposes only and is derived from publicly available recall notices. It supplements but does not replace official agency classifications or safety instructions.
Check Your Product
According to the U.S. Consumer Product Safety Commission (CPSC)
Product
Crown Aruba IV (AWR Series) gas-fired hot water boilers
Brand
Crown Boiler Company LLC, of Philadelphia, Pennsylvania
Lot Codes / Batch Numbers
Not specified in CPSC notice. Check official source for details.
Product Images
Source: U.S. Consumer Product Safety Commission
Crown Boiler Company LLC, of Philadelphia, Pennsylvania is recalling Crown Aruba IV (AWR Series) gas-fired hot water boilers. The hazard is: The blocked vent switch (BVS) can fail to shut down the burners if the boilers are installed at alti. Based on CPSC recall notice.
Summary derived from CPSC notice
The following details were not provided by CPSC: UPC codes.
Reason for Recall
As stated by CPSC
This recall involves Crown Boiler Aruba IV (AWR Series) gas-fired hot water boilers powered by natural gas and LP (propane) gas. This recall only involves boilers configured for use at altitudes above 2,000 feet. The model name Aruba IV is not found on the label. The boiler is red and gray and 39.5 inches high. A "Crown" logo appears on the upper front-center of the unit. The model number is shown on the boiler's rating plate, located on the top of the right side of the boiler where shown. Crown is printed on the side, and the model number for Aruba IV is located on a large white label on the red metal side of the boiler. The following model numbers are included in this recall regardless of date manufactured: AWR070BLST3P8U AWR105BLST3P8U AWR140BLST3P8U AWR175BLT3HU1 AWR070BLT3HU1 AWR105BLT3HU1 AWR140BLT3HU1 AWR175BNST3P8U AWR070BNST3P8U AWR105BNST3P8U AWR140BNST3P8U AWR175BNT3HU1 AWR070BNT3HU1 AWR105BNT3HU1 AWR140BNT3HU1 AWR175ELST2P8U AWR070ELST2P8U AWR105ELST2P8U AWR140ELST2P8U AWR175ENST2P8U AWR070ENST2P8U AWR105ENST2P8U AWR140ENST2P8U AWR210BNST3P8U AWR245BLST3P8U AWR280BNST3P8U AWR210BNT3HU1 AWR245BLT3HU1 AWR280BNT3HU1 AWR210ELST2P8U AWR245BNST3P8U AWR280ELST2P8U AWR210ENST2P8
Reported concern (CPSC)
The blocked vent switch (BVS) can fail to shut down the burners if the boilers are installed at altitudes above 2,000 feet and the vent system becomes blocked. In such an event, the boiler can emit excessive amounts of carbon monoxide into the building, posing a carbon monoxide (CO) poisoning hazard to consumers.
Recommended Action
Per CPSC guidance
Consumers with the recalled boilers should immediately contact Crown Boiler for a free repair that includes a free replacement main burner gas orifice, and a free replacement blocked vent switch if needed. Consumers who continue using the recalled boilers while awaiting repair should have working carbon monoxide alarms installed outside of sleeping areas and on each floor of the home. Consumers can review Protect Your Family from Carbon Monoxide Poisoning | CPSC.gov for more information about preventing carbon monoxide poisoning.
Verify this information on the official source
For complete details and official instructions, check the U.S. Consumer Product Safety Commission (CPSC) directly.
View official CPSC recall noticePage updated: Jan 11, 2026