Evaporator Coil Drain Pans (Daikin) – expanded product recall (2022)
Hazard assessment based on recall description.
This AI-generated summary is provided for general informational purposes only and is derived from publicly available recall notices. It supplements but does not replace official agency classifications or safety instructions.
Check Your Product
According to the U.S. Consumer Product Safety Commission (CPSC)
Product
Evaporator coil drain pans
Brand
Daikin Comfort Technologies Manufacturing, L.P. (formerly Goodman Manufacturing Company, L.P.) of Houston, Texas
Lot Codes / Batch Numbers
Not specified in CPSC notice. Check official source for details.
Product Images
Source: U.S. Consumer Product Safety Commission
Daikin Comfort Technologies Manufacturing, L.P. (formerly Goodman Manufacturing Company, L.P.) of Houston, Texas is recalling Evaporator coil drain pans. The hazard is: The molded plastic drain pan located at the bottom of the evaporator coil can overheat, melt and def. Based on CPSC recall notice.
Summary derived from CPSC notice
The following details were not provided by CPSC: UPC codes.
Reason for Recall
As stated by CPSC
This recall expands the scope of a previous recall that involved certain evaporator coil drain pans installed with condensing gas furnaces in an up-flow coil configuration. The recall now also includes those drain pans installed with certain configurations of competitor branded (not Goodman, Daikin or Amana-branded) non-condensing residential gas furnaces in a vertical, or "up-flow," coil configuration, as shown in the table below: Type Coil Configuration Affected Furnace Brands Affected Coil Serial Numbers Dates Sold Condensing furnace system Up-Flow (Coil above Furnace) All Prefixes ranging from 1901 through 2101 Jan. 2019 through Nov. 2021 Non-condensing furnace system (Certain configurations) Up-Flow (Coil above Furnace) Any "competitor" brand (excludes Goodman, Daikin or Amana branded furnaces) Prefixes ranging from 1901 through 2101 Jan. 2019 through Nov. 2021 NOTE: Furnace systems that were repaired with a new evaporator coil drain pan between January 2019 and November 2021, with the serial number range listed above, are also included in this recall. Whether a non-condensing furnace system falls within the scope of the expanded recall depends on the location of the burners, which, if unknown, can be verified through DCT's model verification tool at: https://www.recallrtr.com/drainpan. Affected units can be identified through serial numbers found on the evaporator coil or the case, which sits atop the vertically installed furnace. The furnace brand and model number can be found on the furnace on the "Energy Guide" label. Consumers can refer to the instructions on DCT's model verification tool at: https://www.recallrtr.com/drainpan. The model number of the outdoor condenser may also be required and can be found on a label attached to the product.
Reported concern (CPSC)
The molded plastic drain pan located at the bottom of the evaporator coil can overheat, melt and deform, posing a fire hazard.
Recommended Action
Per CPSC guidance
Consumers should contact Daikin Comfort Technologies Manufacturing, L.P. (DCT) to determine whether your unit is included in this recall and to register for the free repair by a qualified technician. DCT is contacting all registered consumers where records indicate their gas furnace system is subject to the expanded recall.
Verify this information on the official source
For complete details and official instructions, check the U.S. Consumer Product Safety Commission (CPSC) directly.
View official CPSC recall noticePage updated: Jan 10, 2026