GOSHEN COACH is recalling certain 2006 GOSHEN GC II vehicles due to equipment issues. THIS WOULD CAUSE THE RESISTOR TEMPERATURE TO RISE TO A POINT WHERE IT WILL MELT AND POSSIBLY IGNITE THE PLASTIC BLOWER HOUSING TO WHICH IT IS MOUNTED..
Summary derived from NHTSA notice
Reason for Recall
As stated by NHTSA
GOSHEN COACH IS RECALLING CERTAIN MODEL YEAR 2006-2007 GOSHEN GC II MOTOR HOMES EQUIPPED WITH TRANS AIR TA 73 EVAPORATORS. THE EVAPORATOR UTILIZES A POWER RESISTOR TO REGULATE BLOWER SPEED. SHOULD A SHORT OCCUR IN THE "LOW OR MEDIUM SPEED" CIRCUIT WHILE THE BLOWER IS IN HIGH SPEED, THE SHORT WILL CAUSE THE SUPPLY VOLTAGE TO FEEDBACK THROUGH THE RESISTOR TO GROUND, NOT DRAWING ENOUGH CURRENT TO TRIP THE FUSE.
Reported concern (NHTSA)
THIS WOULD CAUSE THE RESISTOR TEMPERATURE TO RISE TO A POINT WHERE IT WILL MELT AND POSSIBLY IGNITE THE PLASTIC BLOWER HOUSING TO WHICH IT IS MOUNTED. THE OVERHEATING CAN RESULT IN A FIRE.
Recommended Action
Per NHTSA guidance
GOSHEN COACH IN COOPERATION WITH TRANS AIR WILL INSTALL A THERMAL SHUTDOWN DEVICE IN SERIES WITH THE SPEED RESISTORS. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON NOVEMBER 4, 2010. OWNERS MAY CONTACT TRANS AIR WARRANTY AND SERVICE CENTER AT 1-800-673-2446.