Instrumentation Laboratory ACL TOP Family 50 Series Models as follows: In vitro diagnostic clinical use in the hemostasis laboratory for coagulation and/or fibrinolysis testing in the assessment of thrombosis and/or hemostasis (1) ACL TOP 550 CTS Model Number: 00000280045; (2) ACL TOP 750 CTS Model Number: 00000280055; (3) ACL TOP 350 CTS Model Number: 00000280065; (4) ACL TOP 750 Model Number: 00000280015; (5) ACL TOP 750 LAS Model Number: 000002 Recall
Hazard assessment based on recall description.
This AI-generated summary is provided for general informational purposes only and is derived from publicly available recall notices. It supplements but does not replace official agency classifications or safety instructions.
Check Your Product
According to the U.S. Food and Drug Administration (FDA)
Product
ACL TOP Family 50 Series Models as follows: In vitro diagnostic clinical use in the hemostasis laboratory for coagulation and/or fibrinolysis testing in the assessment of thrombosis and/or hemostasis (1) ACL TOP 550 CTS Model Number: 00000280045; (2) ACL TOP 750 CTS Model Number: 00000280055; (3) ACL TOP 350 CTS Model Number: 00000280065; (4) ACL TOP 750 Model Number: 00000280015; (5) ACL TOP 750 LAS Model Number: 000002
Brand
Instrumentation Laboratory
Lot Codes / Batch Numbers
Model Names UDI (1)ACL TOP 550 CTS 08426950729242, (2)ACL TOP 750 CTS 08426950784067, (3)ACL TOP 350 CTS 08426950784081, (4) ACL TOP 750 08426950784074, (2)ACL TOP 750 CTS v6.3.0 or later, (3)ACL TOP 350 CTS v6.3.0 or later, (4) ACL TOP 750 v6.3.0 or later, (5) ACL TOP 750 LAS v6.3.0 or later, ACL TOP 550 CTS 21112046 23072623, ACL TOP 750 22010516 23060671, ACL TOP 750 CTS 21110860 23071015, ACL TOP 750 LAS 21120879 23071077
Products Sold
Model Names UDI (1)ACL TOP 550 CTS 08426950729242; (2)ACL TOP 750 CTS 08426950784067; (3)ACL TOP 350 CTS 08426950784081; (4) ACL TOP 750 08426950784074; (5) ACL TOP 750 LAS 08426950784050 (6) ACL TOP 970 CL 08430793045476 Software: 1)ACL TOP 550 CTS v6.3.0 or later; (2)ACL TOP 750 CTS v6.3.0 or later; (3)ACL TOP 350 CTS v6.3.0 or later; (4) ACL TOP 750 v6.3.0 or later; (5) ACL TOP 750 LAS v6.3.0 or later; (6) ACL TOP 970 CL Version 1.1.0 (OUS). UPDATE: 10/16/23 Affected Serial Number Range Start SN End SN ACL TOP 350 CTS 21113058 23074369; ACL TOP 550 CTS 21112046 23072623; ACL TOP 750 22010516 23060671; ACL TOP 750 CTS 21110860 23071015; ACL TOP 750 LAS 21120879 23071077
Instrumentation Laboratory is recalling ACL TOP Family 50 Series Models as follows: In vitro diagnostic clinical use in the hemostasis labo due to Sample misidentification could occur under specific conditions and patient management altered based on an incorrectly assigned result. Based on FDA medical device recall database.
Summary derived from FDA notice
Reason for Recall
As stated by FDA
Sample misidentification could occur under specific conditions and patient management altered based on an incorrectly assigned result
Recommended Action
Per FDA guidance
UPDATE: 10/16/23: Update relates to additional ACL TOP Family 50 Series instruments that were installed after the field notification was initiated (Phase I), but prior to inclusion of the notification instructions in start-up kits with new production. During the Installation process, Service field representatives will provide the titled Important Instruction, to the customer. The letter states the same instructions as provided in the Urgent Medical Device Correction Letter initially issued. __________________________________________________________________________ Werfen Issued Urgent Medical Device Correction Letter and Mandatory response tracking form on July 13th, 2023 via email or Certified Mail. Letter states reason for recall, health risk and action to take: Based on the above please take one of the following immediate workflows to mitigate this issue. To avoid the potential sample misidentification, users should not change any samples in the sample rack that have been properly identified. If the user decides they must remove a sample from a sample rack that has been properly identified by the ACL TOP Family 50 Series Instrument, they may do so only after the bar code reader has returned to the home position or the samples have been completely resulted. Alternatively, a user may remove a properly identified sample from a sample rack and must leave that sample rack position empty. x Share this information with your laboratory staff and update your internal procedures, as needed. x Forward this notification to all affected locations in your facility. x Post this notification on all affected systems in your facility. x Retain a copy of this notification for your records. x Complete and return the Mandatory Response Tracking Form to acknowledge the above actions. x Mandatory Response Tracking Record x Return the completed and signed Mandatory Response Tracking Form to: x Fax No.: 1-781-861-4207 Or E-mail: ra-usa.na@werfen.com x Contact Information for
Verify this information on the official source
For complete details and official instructions, check the U.S. Food and Drug Administration (FDA) directly.