Surgeloc Surge Devices (Schneider Electric) – Fire Hazard (2020)
Check Your Product
According to the U.S. Consumer Product Safety Commission (CPSC)
Product
Surgeloc Surge Protection Devices
Brand
Schneider Electric Systems USA, Inc., of Foxboro, Mass.
Lot Codes / Batch Numbers
Not specified in CPSC notice. Check official source for details.
Product Images
Source: U.S. Consumer Product Safety Commission
Schneider Electric Systems USA, Inc., of Foxboro, Mass. is recalling Surgeloc Surge Protection Devices. The hazard is: The Surgeloc Surge Protection Device can experience an arc event, which can result in a fire hazard.. Based on CPSC recall notice.
Summary derived from CPSC notice
The following details were not provided by CPSC: UPC codes.
Reason for Recall
As stated by CPSC
This recall involves Schneider Electric Surgeloc Surge Protection Devices. The 3-wire and 4-wire devices are primarily installed in commercial/industrial applications and may include some residential applications. They are black rectangular-shaped devices with a green plastic rimmed meter and a white label with "Square D by Schneider Electric," with the date code and the catalog number on the front. The recalled devices were manufactured from January 1, 2013 (date code 13011) through August 24, 2020 (date code 20352). The date codes are in the YYWWD format (example: 20452 = year 2020, week 45, day 2 Monday; the day is optional). The date code is located on the front of the device. Catalog numbers included in the recall include the following: Voltage Surge Current Rating NQ Panelboard Units - Surge Cat No. 120/240 V, 1 Phase, 3-wire + ground 80 kA SSP01BIA08PBQ1 100 kA SSP01BIA10PBQ1 120 kA SSP01BIA12PBQ1 160 kA SSP01BIA16PBQ1 200 kA SSP01BIA20PBQ1 240kA SSP01BIA24PBQ1 208Y/120 V, 3-Phase, 4-wire + ground Wye 80 kA SSP02BIA08PBQ1 100 kA SSP02BIA10PBQ1 120 kA SSP02BIA12PBQ1 160 kA SSP02BIA16PBQ1 200 kA SSP03BIA20PBQ1 240kA SSP03BIA24PBQ1 240Y/120 V, 3-Phase, 4-wire + ground High-leg Delta 80 kA SSP03BIA08PBQ1 100 kA SSP03BIA10PBQ1 120 kA SSP03BIA12PBQ1 160 kA SSP03BIA16PBQ1 200 kA SSP03BIA20PBQ1 240kA SSP03BIA24PBQ1
Reported concern (CPSC)
The Surgeloc Surge Protection Device can experience an arc event, which can result in a fire hazard.
Recommended Action
Per CPSC guidance
Consumers should immediately stop using the recalled surge protection devices and contact Schneider Electric for instructions on receiving a free equivalent replacement surge protector.
Verify this information on the official source
For complete details and official instructions, check the U.S. Consumer Product Safety Commission (CPSC) directly.
View official CPSC recall noticePage updated: Jan 10, 2026