Due to affected devices that may have bent female IUI connector and may not be operable and potentially cause delays in the start of the infusion or monitoring.
Due to affected devices that may have bent female IUI connector and may not be operable and potentially cause delays in the start of the infusion or monitoring.
Incomplete insertion of the patient connector of the Streamline Airless System Hemodialysis Bloodline to the Locksite may result in the potential for occlusion during prograde rinseback procedures. If the patient connector is not fully inserted into the Locksite, the internal septum may not open fully enough to prevent restrictions to flow. may cause delays in therapy while clinicians are forced to switch to retrograde flow method
Atellica CH Microalbumin_2 (ALB_2) and the ADVIA Chemistry Microalbumin_2 (ALB_2) are not meeting the High-Dose Hook Effect claim/Prozone Effect claim as stated in the Instructions for Use (IFU) on the Atellica CH, Atellica CI Analyzers, ADVIA 1800 Chemistry Systems, ADVIA 2400 Chemistry Systems, and ADVIA Chemistry XPT Systems, may result in erroneously depressed microalbumin patient results.
Atellica CH Microalbumin_2 (ALB_2) and the ADVIA Chemistry Microalbumin_2 (ALB_2) are not meeting the High-Dose Hook Effect claim/Prozone Effect claim as stated in the Instructions for Use (IFU) on the Atellica CH, Atellica CI Analyzers, ADVIA 1800 Chemistry Systems, ADVIA 2400 Chemistry Systems, and ADVIA Chemistry XPT Systems, may result in erroneously depressed microalbumin patient results.
Incomplete insertion of the patient connector of the Streamline Airless System Hemodialysis Bloodline to the Locksite may result in the potential for occlusion during prograde rinseback procedures. If the patient connector is not fully inserted into the Locksite, the internal septum may not open fully enough to prevent restrictions to flow. may cause delays in therapy while clinicians are forced to switch to retrograde flow method
If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliters using multiplier 100 instead of 1000, resulting values 10x smaller than actual, which could contribute misdiagnosis or negatively influence patient management
CFMOTO Powersports, Inc. (CFMOTO) is recalling certain 2023 Ibex 800 S and Ibex 800 T motorcycles. The throttle wire may bend excessively and break, resulting in a loss of throttle response and an engine stall.
REV Recreation Group (REV) is recalling certain 2019-2025 Holiday Rambler Admiral, 2023-2025 Holiday Rambler Eclipse, Fleetwood Flex, and 2019-2024 Fleetwood Flair motorhomes. The exterior patio outlet may lack GFCI protection when powered by the generator or shore cord.
Contamination with foreign substance matter
Due to interfacing issues between the implant trial and inserter of the lumbar intervertebral fusion device.
Rosenbauer America (Rosenbauer) is recalling certain 2023-2024 Commander fire trucks equipped with certain independent front suspension assemblies. The lower control arm retention bolts can become brittle and break after being tightened.
BMW of North America, LLC. (BMW) is recalling certain 2012-2015 X1 sDrive28i, X1 xDrive28i, 2012-2016 Z4 sDrive28i, 528i, 528i xDrive, 328i, 328xi, 2016-2018 X5 xdrive 40e, 2014-2016 228i, 228xi, 428i, 428i xDrive, 328xi Gran Turismo, 2013-2017 X3 sDrive28i, X3 xDrive28i, 2015-2018 X4 xDrive28i, 2015-2016 428xi vehicles. An improperly sealed electrical connector on the water pump may be exposed to water and short circuit.
Heartland Recreational Vehicles (Heartland) is recalling certain 2024-2025 Torque travel trailers, equipped with optional Onan 5.5 generators. These generators may not be properly vented and allow the generator to overheat or prevent exhaust gas from escaping properly.
This product labeling does not adequately provide warning about the risks associated with the use of damaged batteries or batteries past the intended use life.
Kido Sports Co., Ltd. (Kido Sports) is recalling certain Scorpion EXO-C90 and Harley-Davidson HD-X06 helmets, sizes XS, S, M, L, XL, and 2XL. The helmets may not stay securely fastened during a crash. As such, these helmets fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 218, "Motorcycle Helmets."
SPL Parts Inc (SPL) is recalling certain Front Suspension Lower Control Arm Kits equipped with replacement bolts. The lower control arm retention bolts could become brittle and break after being tightened.
Cruiser RV is recalling certain 2024-2025 Stryker travel trailers, equipped with optional Onan 5.5 generators. These generators may not be properly vented and allow the generator to overheat or prevent exhaust gas from escaping properly.
This product labeling does not adequately provide warning about the risks associated with the use of damaged batteries or batteries past the intended use life.
The term Bladder Stone was incorrectly translated in both Spanish and Portuguese to Kidney Stone(Clculo renal) on the systems Graphical User Interface (GUI), a potential to deliver an incorrect or unintended amount of energy to the patients anatomy.