Hamilton Co HAMILTON HEATER SHAKER, 115 VAC/ 230 VAC, 750 VA, Power Consumption 41V/ 100W (max.), Relative Humidity 15% - 85% no condensation. REF 19903400 Recall
Hazard assessment based on recall description.
This AI-generated summary is provided for general informational purposes only and is derived from publicly available recall notices. It supplements but does not replace official agency classifications or safety instructions.
Check Your Product
According to the U.S. Food and Drug Administration (FDA)
Product
HAMILTON HEATER SHAKER, 115 VAC/ 230 VAC, 750 VA, Power Consumption 41V/ 100W (max.), Relative Humidity 15% - 85% no condensation. REF 19903400
Brand
Hamilton Co
Lot Codes / Batch Numbers
Various Part Numbers: Hamilton Company PART NUMBER/ DESCRIPTION 188318/ HHS2, 2MM ORBIT, CUSTOMIZED, 188319/ HHS2, 3MM ORBIT, CUSTOMIZED, 199000/ HHS 0.5 MTP FLAT BOTTOM, 199001/ HHS 2.0 MTP FLAT BOTTOM, 199002/ PLEASE USE PN: 199034, 199007/ HHS 2.0 NUNC DWP 96 2ML, 199008/ HHS 3.0 NUNC DWP 96 2ML, 199009/ HHS 1.5 MTP FLAT BOTTOM, 199011/ HHS, 1.5MM, NUNC, 96DWP, 2ML, 199027/ HHS 1.5 MM SARSTEDT 48X1.5ML, 199033/ HHS2, 2MM ORBIT, MTP FLT BOTTOM, 199034/ HHS2, 3MM ORBIT, MTP FLT BOTTOM, 199037/ HHS 1.5MM NUNC DWP 96 2ML, 199038/ HHS2, 2MM ORBIT, NUNC DWP96 2M, 199039/ HHS2, 3MM ORBIT, NUNC DWP96 2M, 199085/ HHS 3.0 FLIPTUBE RACK, 199474/ HHS 3.0 BIO-RAD DWP FSD, 809018/ HHS 3.0 AUTOLYS, 0201710-001/ HHSADVWR40002-012DWP96CON2ML, 0202697-002/ HHS, RGT TRUGH HOLD FRAME, LID, 0203408-002/ HHS, 199034, 188219APE/ HHS 3.0MM AMPLITUDE, 199033R/ HHS2, 2MM ORBIT, MTP FLT BOT REF, 199034R/ HHS2, 3MM ORBIT, MTP FLT BTM, 65608-01/ HHS2, 3MM ORBIT, MPT, 65608-01R/ HHS2, 3MM ORBIT, MPT, REFURB, 6601885-01/ KIT, HHS, 3 MM ORBIT, ML PREP, 6601885-02/ KIT, HHS, 2 MM ORBIT, ML PREP, 95379-01/ HHS2, 3MM ORBIT, DWP96, EXACT SCI, Hamilton Bonaduz AG PART NUMBER DESCRIPTION 188319/ Hamilton Heater Shaker, flat bottom adapter (APE), 199033/ Hamilton Heater Shaker, flat bottom adapter, 199034/ Hamilton Heater Shaker, flat bottom adapter, 199037/ HHS 1.5 NUNC DWP 96 2ML, 199038/ HHS 2.0 NUNC DWP 96 2ML, 199039/ Hamilton Heater Shaker 3.0 Nunc DWP, 199068/ HHS 1.5 ROCHE, 199474/ HHS 3.0mm BIO-RAD FSD, 199525/ HHS 2.0 MTP V BOTTOM, 809018/ HHS 3.0 AUTOLYS, 816040/ HHS 1.5mm 2G, 816061/ HHS 1.5 NUNC DWP 96 2ML TIG, 819273/ HHS 3.0 V-BOTTOM, 10069018/ HHS 3.0 NUNC DWP 96 2ML TIG
Products Sold
Various Part Numbers: Hamilton Company PART NUMBER/ DESCRIPTION 188318/ HHS2,2MM ORBIT,CUSTOMIZED; 188319/ HHS2,3MM ORBIT,CUSTOMIZED; 199000/ HHS 0.5 MTP FLAT BOTTOM; 199001/ HHS 2.0 MTP FLAT BOTTOM; 199002/ PLEASE USE PN: 199034; 199007/ HHS 2.0 NUNC DWP 96 2ML; 199008/ HHS 3.0 NUNC DWP 96 2ML; 199009/ HHS 1.5 MTP FLAT BOTTOM; 199011/ HHS,1.5MM,NUNC,96DWP,2ML; 199027/ HHS 1.5 MM SARSTEDT 48X1.5ML; 199033/ HHS2,2MM ORBIT,MTP FLT BOTTOM; 199034/ HHS2,3MM ORBIT,MTP FLT BOTTOM; 199037/ HHS 1.5MM NUNC DWP 96 2ML; 199038/ HHS2,2MM ORBIT,NUNC DWP96 2M; 199039/ HHS2,3MM ORBIT,NUNC DWP96 2M; 199085/ HHS 3.0 FLIPTUBE RACK; 199474/ HHS 3.0 BIO-RAD DWP FSD; 809018/ HHS 3.0 AUTOLYS; 0201710-001/ HHSADVWR40002-012DWP96CON2ML; 0202697-002/ HHS,RGT TRUGH HOLD FRAME,LID; 0203408-002/ HHS,199034; 188219APE/ HHS 3.0MM AMPLITUDE; 199033R/ HHS2,2MM ORBIT,MTP FLT BOT REF; 199034R/ HHS2,3MM ORBIT,MTP FLT BTM; 65608-01/ HHS2,3MM ORBIT, MPT; 65608-01R/ HHS2,3MM ORBIT, MPT,REFURB; 6601885-01/ KIT,HHS,3 MM ORBIT,ML PREP; 6601885-02/ KIT,HHS,2 MM ORBIT,ML PREP; 95379-01/ HHS2,3MM ORBIT,DWP96,EXACT SCI; Hamilton Bonaduz AG PART NUMBER DESCRIPTION 188319/ Hamilton Heater Shaker, flat bottom adapter (APE); 199033/ Hamilton Heater Shaker, flat bottom adapter; 199034/ Hamilton Heater Shaker, flat bottom adapter; 199037/ HHS 1.5 NUNC DWP 96 2ML; 199038/ HHS 2.0 NUNC DWP 96 2ML; 199039/ Hamilton Heater Shaker 3.0 Nunc DWP; 199068/ HHS 1.5 ROCHE; 199474/ HHS 3.0mm BIO-RAD FSD; 199525/ HHS 2.0 MTP V BOTTOM; 809018/ HHS 3.0 AUTOLYS; 816040/ HHS 1.5mm 2G; 816061/ HHS 1.5 NUNC DWP 96 2ML TIG; 819273/ HHS 3.0 V-BOTTOM; 10069018/ HHS 3.0 NUNC DWP 96 2ML TIG
Hamilton Co is recalling HAMILTON HEATER SHAKER, 115 VAC/ 230 VAC, 750 VA, Power Consumption 41V/ 100W (max.), Relative Humid due to There is a risk that the device can start a fire if flammable liquids contact and enter the device.. Based on FDA medical device recall database.
Summary derived from FDA notice
Reason for Recall
As stated by FDA
There is a risk that the device can start a fire if flammable liquids contact and enter the device.
Recommended Action
Per FDA guidance
An URGENT: MEDICAL DEVICE CORRECTION notifications was sent to the consignees via email of 01/15/2021. Hamilton Heater Shaker upgrades were started on 15-JAN- 2021. A device upgrade has been developed to mitigate the risk of the device catching fire. The upgrade consists of a plastic tray within the body of the Hamilton Heater Shaker and a redesigned base plate. These upgrades prevent liquid from reaching the electrical components of the device. The recall notification states: " Hamilton Company Field Service will contact your organization to schedule a time to upgrade your Hamilton Heater Shaker(s) to mitigate this risk. For customers who perform their own field service, a zero-dollar purchase order can be submitted to RoboticsOEMsales@hamiltoncompany .com to obtain upgrade kits. The upgrade consists of a plastic tray within the body of the Hamilton Heater Shaker and a redesigned base plate. These upgrades prevent liquid from reaching the electrical components of the device. This upgrade will be supplied free-of-charge and does not impact the functionality of the device. Until the upgrade is performed, it is crucial to observe the following safety best practices: o Methods should include labware touch-off presence checks to ensure the labware is ready to receive liquid. o On-deck waste and fluid collection devices should be placed at least one track away from Hamilton Heater Shakers or any other heating device. Recipients of this notice shall forward it to all customers to whom they have sold Hamilton Heater Shakers. Please complete and return the attached Acknowledgement and Receipt Form to productrecalls@hamiltoncompany.com . On this form, please indicate if you have experienced a fire on your device. If you experience a fire on your device in the future, please notify your Hamilton representative immediately and cease using the device. Please contact productrecalls@hamiltoncompany.com or call 800-527-5269 between 7:00am and 3:30pm P
Verify this information on the official source
For complete details and official instructions, check the U.S. Food and Drug Administration (FDA) directly.
View official FDA recall noticeDistribution
As reported by FDA
AL, AZ, AR, CA, CO, CT, DE, FL, GA, HI, ID, IL, IN, IA, KS, KY, LA, ME, MD, MA, MI, MN, MS, MO, MT, NV, NH, NJ, NM, NY, NC, OH, OK, OR, PA, SC, TN, TX, UT, VA, WA, WI, WY, DC
Page updated: Jan 10, 2026