Medical device and health technology recalls from FDA. Includes diagnostic equipment, implants, monitors, and therapeutic devices.
Product complaints were received describing the A820 myPTM app taking longer than expected for patients to interact with their implantable pump.
The machine side connector of the filter HME may be occluded by plastic which prevents proper airflow. The issue may lead to ventilation bag malfunction in which the user is unable to inflate/deflate properly during manual ventilation. Potential risks to health include oxygen deprivation, leading to respiratory distress and medical complications.
Kits contain recalled components due to reports of reduced skin barrier wear time. This refers to a shorter duration that a skin barrier can effectively adhere to and protect the skin before it needs to be replaced.
The machine side connector of the filter HME may be occluded by plastic which prevents proper airflow. The issue may lead to ventilation bag malfunction in which the user is unable to inflate/deflate properly during manual ventilation. Potential risks to health include oxygen deprivation, leading to respiratory distress and medical complications.
The MSOT Acuity Echo does not include an adequate instruction for safe operation of the device. The previous version of the user manuals contained a wrong value for the Nominal Ocular Hazard Distance (NOHD).
Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms.
Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms.
Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms.
Software issues could potentially result in: 1) delays in accessing dispensing software application, 2) wrong therapy (dose, item, timing, etc.), or 3) unauthorized access and/or compliance related issues
Labeling is insufficient regarding delays in access to medication. The firm is strengthening the label as an additional risk mitigation.
Precision Thin blade attachments have a potential to be out of measurement specifications, preventing them from securely fitting into the compatible handpiece.
Three lots of Rapid fFN Specimen Collection kit (901164, 901165, and 904850) contain Rapid fFN Specimen Collection Tubes which may be empty, underfilled, or overfilled with extraction buffer. The transport tubes are used with the Fetal Fibronectin Enzyme Immunoassay and Rapid fFN for the TLiIQ System which aids in assessing the risk of preterm delivery. The use of empty transport tubes or transport tubes containing insufficient extraction buffer volume may result in invalid results and/or delays in obtaining results. Additionally, the use of underfilled tubes may result in false positive results and the use of overfilled tubes may result in false negative results.
Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms.
It was identified internally that two commingle events occurred where the metal support post within the polyethylene articular surface was assembled incorrectly for three units within the scope.
Sysmex was made aware of a report of false results due to carry-over caused by the sporadic omission of the probe wash step during antibody pipetting on the PS-10 Sample Preparation System.
Due to an observed trend of neurovascular events
Medline is recalling medical convenience kits which were assembled with specific Coloplast Foley catheters and Prostatic catheters which were subsequently recalled due to a potential sterility issue detected during testing.
Certain implants in the Irix-A Lumbar Fusion System were distributed while labeled with an incorrect expiration date.
Their is a potential that implanted pulse generators may stop delivering therapy due to an internal component issue.
Their is a potential that implanted pulse generators may stop delivering therapy due to an internal component issue.